Write advantages and disadvantages of electron microscope over optical microscope? Explain.

15 marks

Answer

Electron microscopes (EM) offer significant improvements over optical microscopes (OM) by utilizing a beam of electrons instead of visible light, which overcomes the diffraction limit imposed by the wavelength of light.

Advantages of Electron Microscope:

  • Superior Resolution: Because electrons have a much shorter de Broglie wavelength than visible light, EMs can achieve resolutions in the sub-nanometer range, whereas optical microscopes are limited to approximately 200 nm.
  • High Magnification: EMs can provide magnifications exceeding 1,000,000x, allowing for the observation of atomic structures and fine details of nanomaterials that are invisible to optical systems.
  • Depth of Field: EMs possess a significantly larger depth of field compared to optical microscopes, providing a 3D-like appearance in Scanning Electron Microscopy (SEM) images.
  • Analytical Capabilities: EMs are often equipped with detectors like Energy Dispersive X-ray Spectroscopy (EDS) to provide elemental composition and chemical mapping of the specimen.

Disadvantages of Electron Microscope:

  • Sample Preparation: Samples must be dehydrated, conductive (often requiring metal coating), and thin enough for the electron beam to penetrate (in TEM), which is a complex and time-consuming process.
  • Vacuum Requirement: EMs require a high vacuum environment to prevent electron scattering by air molecules, meaning living specimens cannot be observed.
  • Cost and Complexity: EMs are expensive to purchase, maintain, and operate, requiring specialized infrastructure and highly trained personnel.
  • Artifacts: The intensive preparation process (fixation, dehydration, staining) can introduce artifacts, potentially leading to misinterpretation of the specimen's native structure.
  • No Color Imaging: EMs produce images based on electron density, resulting in grayscale images; they cannot capture the natural color of a sample.
2

How to adjust the beam spot size in Scanning electron microscope? Explain.

15 marks

Answer

In a Scanning Electron Microscope (SEM), the beam spot size is the diameter of the electron probe at the specimen surface. Adjusting this parameter is a fundamental trade-off between spatial resolution and signal-to-noise ratio. The spot size is primarily controlled by the interaction of the electron gun, the condenser lens system, and the final objective lens aperture.

The adjustment is achieved through the following mechanisms:

  • Condenser Lens Current: The condenser lenses control the convergence angle of the electron beam. By increasing the current through the condenser lenses, the beam is focused more strongly, leading to a smaller crossover point and a reduced spot size at the specimen. Conversely, decreasing the current results in a larger spot size.
  • Aperture Selection: The final objective aperture acts as a physical filter for the electron beam. Inserting a smaller diameter aperture blocks the peripheral electrons of the beam that have higher spherical aberration. This restricts the beam to the central, most coherent part, significantly reducing the spot size at the cost of lower beam current.
  • Working Distance (WD): While not a direct lens setting, the working distance influences the effective spot size. A shorter working distance allows the objective lens to focus the beam more tightly, minimizing the effects of spherical and chromatic aberrations, which results in a smaller, sharper spot size.
  • Gun Bias and Emission Current: Adjusting the bias voltage at the electron gun (specifically in thermionic emitters) controls the emission current. A higher bias reduces the total emission, which can lead to a smaller virtual source size and consequently a smaller final spot size.

In summary, to achieve the smallest spot size for high-resolution imaging, one must use a smaller objective aperture, a shorter working distance, and higher condenser lens excitation. However, this adjustment reduces the total number of electrons reaching the sample, which increases noise levels in the image, requiring a balance based on the specific requirements of the sample being characterized.

3

Differentiate the Bright field imaging and Dark field imaging.

15 marks

Answer

Sign in to view the complete answer paper.

4

Explain the principle and instrumentation of AFM.

15 marks

Answer

Sign in to view the complete answer paper.

5

Explain in detail about the IR spectroscopy.

15 marks

Answer

Sign in to view the complete answer paper.

6

Discuss about the Primary Metallic Crystalline Structures of BCC, FCC and HCP.

15 marks

Answer

Sign in to view the complete answer paper.

7

What is Bragg’s law of diffraction? Explain the powder method.

15 marks

Answer

Sign in to view the complete answer paper.

8

Explain in detail about the Raman spectroscopy.

15 marks

Answer

Sign in to view the complete answer paper.