Explain the theory and principle in which separation occurs based on m/e.
Answer
Mass spectrometry separates ions based on their mass-to-charge ratio (m/z). The process begins with the ionization of the sample, where molecules are converted into gas-phase ions. These ions are then accelerated by an electric field into a mass analyzer.
In the analyzer, ions are subjected to electromagnetic fields that exert a force proportional to their mass and charge. According to Newton's second law and Lorentz force principles, the trajectory of an ion is determined by its m/z value. For example, in a magnetic sector analyzer, the magnetic field deflects ions in a circular path with a radius r defined by the equation:
where B is the magnetic field strength, V is the accelerating voltage, m is the mass of the ion, and z is the charge. Ions with different m/z values follow different paths, allowing them to be spatially or temporally separated. By varying the magnetic field or the accelerating voltage, ions of specific m/z values are sequentially focused onto a detector, which records the intensity of the ion current, resulting in a mass spectrum.
Explain the methodology of the radio immuno assay.
Answer
Radioimmunoassay (RIA) is a highly sensitive competitive binding technique used to measure the concentration of antigens by using antibodies and radiolabeled antigens. The methodology follows these steps:
- Preparation of a standard curve using known concentrations of unlabeled antigen.
- Incubation of a fixed, limited amount of specific antibody with a constant amount of radiolabeled antigen (tracer) and the unknown sample containing unlabeled antigen.
- Competitive binding occurs where the unlabeled antigen from the sample and the radiolabeled antigen compete for the limited binding sites on the antibody.
- Separation of the antibody-bound antigen from the free antigen using methods like charcoal adsorption, precipitation, or solid-phase separation.
- Measurement of the radioactivity in either the bound or free fraction using a scintillation counter.
- Calculation of the unknown concentration by comparing the radioactivity of the sample to the standard curve, where the amount of bound radiolabeled antigen is inversely proportional to the concentration of unlabeled antigen in the sample.
Determine the Miller indices value for the planes (shaded region) marked in the cubic unit cell for 6 crystal structures as represented below.
Answer
Sign in to view the complete answer paper.
Explain the theory and principle of extraction technique in which traditionally Craig apparatus was used.
Answer
Sign in to view the complete answer paper.
Explain the principle of an instrumentation method in which Bragg’s Law is involved.
Answer
Sign in to view the complete answer paper.
List out the applications of an instrument in which fast atom bombardment is used as one of the ion source.
Answer
Sign in to view the complete answer paper.
Mention calibration parameters and Explain in detail the calibration of an instrument which works based on fluorescence phenomena.
Answer
Sign in to view the complete answer paper.
List out the differences between H-NMR and C-NMR.
Answer
Sign in to view the complete answer paper.
How many spin states are possible for 1H nucleus.
Answer
Sign in to view the complete answer paper.
What is meant by (n+1) rule in spin-spin coupling explain with an example.
Answer
Sign in to view the complete answer paper.
List out various detectors and explain in detail any two detectors of an instrumentation in which the ionization techniques are used as source.
Answer
Sign in to view the complete answer paper.
Draw a neat labelled block diagram of thermo analytical instrument which examines the mass change of a sample as a function of temperature or time.
Answer
Sign in to view the complete answer paper.
Classify and explain in detail various types of validation as per ICH guidelines.
Answer
Sign in to view the complete answer paper.
Explain in detail the principle involved in a hyphenated technique in which coated plates are used as stationary phase and mention various detectors used in it.
Answer
Sign in to view the complete answer paper.
List out the applications for instrumentation technique in which chemical shifts are involved.
Answer
Sign in to view the complete answer paper.
Explain in detail various factors affecting a curve when a difference in temperature is measured between a sample and reference material when they are subjected to controlled temperature programme.
Answer
Sign in to view the complete answer paper.