JNTU B.Pharmacy IV ADVANCED INSTRUMENTATION TECHNIQUES Previous Question Paper (July/August - 2022 - R17)
Answer any Five Questions. All Questions Carry Equal Marks.
Main
What is chemical shift? Explain the factors affecting chemical shift.
Answer
Chemical shift is the variation in the resonance frequency of a nucleus relative to a standard reference compound (typically Tetramethylsilane, TMS) due to the magnetic shielding effects of surrounding electrons. It is expressed in parts per million (ppm) and is independent of the external magnetic field strength.
Factors affecting chemical shift include:
- Electronegativity: Electron-withdrawing groups decrease electron density around the nucleus (deshielding), causing a downfield shift to higher ppm values.
- Magnetic Anisotropy: The presence of pi-electron systems (e.g., benzene rings, carbonyl groups) creates local magnetic fields that shield or deshield protons depending on their spatial orientation.
- Hydrogen Bonding: Protons involved in hydrogen bonding are deshielded, resulting in a shift toward higher ppm.
- Solvent Effects: The polarity and magnetic properties of the solvent can interact with the solute, altering the local electronic environment of the nuclei.
Explain the instrumentation of NMR spectroscopy.
Answer
The instrumentation of an NMR spectrometer consists of several critical components designed to generate, detect, and process magnetic resonance signals:
- Magnet System: Provides a strong, highly homogeneous, and stable magnetic field (B₀). Modern instruments use superconducting magnets cooled by liquid helium.
- Probe/Sample Holder: Holds the sample tube within the magnetic field and contains the radiofrequency (RF) transmitter and receiver coils.
- RF Transmitter: Generates short, high-power pulses of radiofrequency radiation at the Larmor frequency to excite the nuclei from the lower energy spin state to the higher energy state.
- RF Receiver: Detects the weak oscillating signal (Free Induction Decay or FID) emitted by the nuclei as they relax back to equilibrium.
- Sweep Generator/Frequency Synthesizer: Ensures precise control over the irradiation frequency to maintain resonance conditions.
- Computer/Data Processing System: Performs the Fourier Transform (FT) to convert the time-domain FID signal into a frequency-domain spectrum and manages data storage and integration.
What is Fragmentation? Discuss the fragmentation rules.
Answer
Sign in to view the complete answer paper.
Explain the principle and applications of mass spectroscopy.
Answer
Sign in to view the complete answer paper.
Write the principles and applications of DTA.
Answer
Sign in to view the complete answer paper.
Describe the instrumentation of Differential Scanning Calorimetry (DSC).
Answer
Sign in to view the complete answer paper.
Enumerate the basic aspects of crystals and explain the rotating Crystal techniques.
Answer
Sign in to view the complete answer paper.
Describe the instrumentation of TGA.
Answer
Sign in to view the complete answer paper.
What is calibration? Write the calibration of UV-visible spectrophotometer.
Answer
Sign in to view the complete answer paper.
How do you calibrate HPLC?
Answer
Sign in to view the complete answer paper.
Write the principle, different method, limitations and applications of RIA.
Answer
Sign in to view the complete answer paper.
Write the principle, method and applications of the following:
GC-MS/MS
Answer
Sign in to view the complete answer paper.
HPTLC/MS.
Answer
Sign in to view the complete answer paper.