JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD

JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD B.Tech III DESIGN ESTIMATION AND COSTING OF ELECTRICAL SYSTEMS Previous Question Paper (August - 2022 - R16)

B.Tech | III | II | R16 | August - 2022

Answer PaperPaper Code: 136EWMaximum Marks: 75Time: 3 Hours

Answer any five questions

All questions carry equal marks

Main

115 marks
a

How to protect the electrical installations from different faults? Explain.

7 marks

Answer

Electrical installations are protected from faults through a combination of protective devices and proper system design. The primary objective is to detect abnormal conditions and isolate the faulty section quickly to prevent damage and ensure safety.

  • Fuses: Act as the simplest form of protection by melting when current exceeds a predetermined limit, effectively breaking the circuit during short circuits or severe overloads.
  • Circuit Breakers (MCB/MCCB/ACB): These devices provide both overload and short-circuit protection. They can be reset after clearing the fault, unlike fuses, and offer more precise tripping characteristics.
  • Residual Current Devices (RCD/ELCB): Essential for earth leakage protection. They monitor the balance between phase and neutral currents and trip if a leakage current is detected, preventing electric shocks.
  • Earthing: A robust earthing system ensures that metallic enclosures remain at zero potential during insulation failure, allowing fault current to flow to the ground and triggering protective devices.
  • Surge Protection Devices (SPD): Protect sensitive equipment from transient over-voltages caused by lightning strikes or switching operations.
  • Relays: Used in larger installations to detect specific faults like over-current, under-voltage, or phase reversal, and send a signal to the circuit breaker to trip.
b

What are the guidelines for the installation of fittings? Explain.

8 marks

Answer

The installation of electrical fittings must adhere to standard safety codes to ensure durability and operational safety. Key guidelines include:

  • Mounting Heights: Switches and socket outlets should be installed at standardized heights (typically 1.3 meters for switches and 0.2 meters for sockets from the floor level) to ensure accessibility and safety from moisture.
  • Accessibility and Clearance: Fittings must be placed in locations that are easily accessible for operation and maintenance, while maintaining adequate clearance from water sources (e.g., sinks, showers) to prevent accidental contact.
  • Wiring Connections: All connections must be tight and secure to prevent arcing and overheating. Proper color coding of wires (Phase: Red/Brown, Neutral: Black/Blue, Earth: Green/Yellow) must be strictly followed.
  • Protection from Environment: In damp or outdoor locations, fittings must have the appropriate IP (Ingress Protection) rating to prevent the entry of moisture and dust.
  • Mounting Surfaces: Fittings should be mounted on non-combustible surfaces. If mounted on wooden or flammable surfaces, an insulating base or block must be used.
  • Load Capacity: Ensure that the chosen fittings, such as socket outlets, are rated for the maximum current load of the appliances they are intended to serve to prevent thermal degradation.
  • Earthing Continuity: All metallic parts of the fittings must be effectively bonded to the earthing terminal of the installation to ensure safety in the event of an insulation failure.
215 marks
a

Discuss in detail about the Indian electricity rules.

7 marks

Answer

Sign in to view the complete answer paper.

b

What is the procedure followed in locating main and distribution boards? Explain.

8 marks

Answer

Sign in to view the complete answer paper.

3

How do we estimate and cost the material in electrical installation of residential buildings? Explain.

15 marks

Answer

Sign in to view the complete answer paper.

4

How do we estimate and cost the material in electrical installation of commercial buildings? Explain.

15 marks

Answer

Sign in to view the complete answer paper.

5

Estimate the material required for transmitting the power through a transmission line.

15 marks

Answer

Sign in to view the complete answer paper.

6

Explain the mechanical design of overhead lines in detail. Estimate the material required.

15 marks

Answer

Sign in to view the complete answer paper.

715 marks
a

Explain about various types of substations.

7 marks

Answer

Sign in to view the complete answer paper.

b

Estimate the material required for floor mounted type substations.

8 marks

Answer

Sign in to view the complete answer paper.

8

What are the various types of light sources? Explain in brief.

15 marks

Answer

Sign in to view the complete answer paper.

About this paper

This page contains the solved question paper with answers of DESIGN ESTIMATION AND COSTING OF ELECTRICAL SYSTEMS from JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD for B.Tech CE III II, August - 2022, R16.

For the question paper without answers, switch to the Question Paper tab.

Other papers in DESIGN ESTIMATION AND COSTING OF ELECTRICAL SYSTEMS

Loading Question Papers

Fetching data from database...