JNTU B.Tech II ELECTRICAL MACHINES II Previous Question Paper (April - 2018 - R15)
Note: This question paper contains two parts A and B. Part A is compulsory which carries 25 marks. Answer all questions in Part A. Part B consists of 5 Units. Answer any one full question from each unit. Each question carries 10 marks and may have a, b, c as sub questions.
PART A
Draw the phasor diagram of transformer under zero voltage regulation.
Answer
Zero voltage regulation occurs when the load power factor is leading, such that the voltage drop across the internal impedance is exactly compensated by the phase shift. In the phasor diagram, the secondary terminal voltage V2 is drawn as the reference. The load current I2 leads V2 by an angle φ2. The resistance drop I2R02 is drawn in phase with I2, and the leakage reactance drop I2X02 is drawn at 90 degrees leading to I2. The resultant impedance drop I2Z02 connects the tip of V2 to the no-load induced EMF E2. For zero regulation, the magnitude of E2 must be equal to the magnitude of V2, forming an isosceles triangle where the phasor E2 is equal in length to V2.
What is the effect of increase in frequency on hysteresis losses and eddy current losses in a single phase transformer?
Answer
Hysteresis loss (Ph) is given by the formula Ph = η Bmax1.6 f V, where f is the frequency. Since Bmax is inversely proportional to frequency (Bmax ∝ 1/f) for a constant supply voltage, the hysteresis loss becomes proportional to f-0.6. Therefore, an increase in frequency leads to a decrease in hysteresis loss.
Eddy current loss (Pe) is given by the formula Pe = K Bmax2 f2. Substituting the relationship Bmax ∝ 1/f, the expression simplifies to Pe ∝ (1/f)2 * f2, which results in a constant value. Consequently, eddy current loss remains independent of frequency changes when the supply voltage is maintained constant.
What could be the effect if short circuit test is conducted on LV side?
Answer
Sign in to view the complete answer paper.
What will happen if percentage impedances of transformers are unequal in the parallel operation?
Answer
Sign in to view the complete answer paper.
Why is the auto transformer is not used as distribution transformer?
Answer
Sign in to view the complete answer paper.
What is the function of tertiary winding in a 3-ϕ transformer?
Answer
Sign in to view the complete answer paper.
What is the effect of skewing the rotor slots of an induction motor?
Answer
Sign in to view the complete answer paper.
Draw the speed-torque characteristics of a deep-bar double cage induction motor.
Answer
Sign in to view the complete answer paper.
What are the limitations of speed control by conventional methods?
Answer
Sign in to view the complete answer paper.
What will be the effect on torque developed by an induction motor if applied voltage is reduced to half with frequency unchanged?
Answer
Sign in to view the complete answer paper.
PART B
Develop an equation for induced emf in a transformer winding in terms of flux and frequency?
Answer
Sign in to view the complete answer paper.
The secondary winding of step up transformer takes a current of 820 A, when working at full load at 0.8 power factor lagging. The primary current is 30 A at 0.7 power factor lagging, if the transformation ratio is 30:1, calculate the no-load current?
Answer
Sign in to view the complete answer paper.
Draw and explain the full load vector diagram of single phase transformer under lagging load.
Answer
Sign in to view the complete answer paper.
A 100 kVA, 6.6 kV/415V, single phase transformer has an effective impedance of (3 + j10 Ω) referred to h.v side. Estimate full load voltage regulation at 0.8 p.f leading and power factor corresponding to the zero voltage regulation?
Answer
Sign in to view the complete answer paper.
In OC and SC tests of a transformer, explain why the wattmeter in OC test reads core losses and wattmeter in SC test reads copper losses?
Answer
Sign in to view the complete answer paper.
The maximum efficiency of 100 kVA, 3 kV/500 V, 50Hz single phase transformer is 95% which occurs at 3/4 th of full load, unity power factor. If the impedance is 10%, Calculate regulation at full load at 0.8 power factor lagging.
Answer
Sign in to view the complete answer paper.
Describe the experimental test procedure to separate the core losses of a transformer.
Answer
Sign in to view the complete answer paper.
A 1100/400V, 1-phase transformer gave the following test results open circuit test 1100V, 2A, 180W on l.v. side; short circuit test 20V, 25A, 20W on h.v. side Calculate the equivalent circuit constants.
Answer
Sign in to view the complete answer paper.
Derive an expression for approximate relative weights of conductor material in an autotransformer and 2-winding transformer, the primary voltage being V1, and secondary voltage V2. Compare the weights of conductor material when the transformation ratio is 3. Ignore the magnetizing current?
Answer
Sign in to view the complete answer paper.
Explain open delta connection to carry out 3-phase operation with the help of two transformers.
Answer
Sign in to view the complete answer paper.
A Scott connected transformer supplies two single phase furnaces at 200V, each taking 200 kW. The load on the leading phase is at unity power factor and that on the other phase is 0.8 power factor. The three phase input line voltage is 6600 V. Calculate the values of line currents on the 3-phase side. Neglect the magnetizing and core loss currents in the transformers.
Answer
Sign in to view the complete answer paper.
What are its advantages and disadvantages of wound rotor type induction motor?
Answer
Sign in to view the complete answer paper.
Explain the phenomenon of crawling and cogging.
Answer
Sign in to view the complete answer paper.
Explain how starting performance of 3-phase squirrel cage type induction motor is improved by means of double cage rotor windings.
Answer
Sign in to view the complete answer paper.
Explain the phenomenon of crawling and cogging.
Answer
Sign in to view the complete answer paper.
A three phase, 15 kW, 400 V, 50 Hz, 4-pole, delta connected squirrel cage induction motor has the following data: No-load: 400 V, 5.0 A, p.f. 0.2; Blocked rotor: 120 V, 20.0 A p.f. 0.6. The ratio of stator to rotor copper losses on short circuit is assumed to be unity. Draw the circle diagram and determine (a) the full load current and power factor (b) the maximum power developed (c) starting torque.
Answer
Sign in to view the complete answer paper.
Explain the induction motor operation under injection of an e.m.f. into the rotor circuit.
Answer
Sign in to view the complete answer paper.