What is an electric shock? What should you do if someone has had an electric shock? Explain.

7 marks

Answer

An electric shock occurs when an electric current passes through the human body, typically resulting from contact with a live conductor or faulty equipment. The severity depends on the current magnitude, duration, and path through the body, which can cause muscle contractions, burns, respiratory failure, or cardiac arrest.

If someone has received an electric shock, follow these steps immediately:

  1. Ensure your own safety by turning off the power source at the main switch or circuit breaker before touching the victim.
  2. If the power cannot be cut, use a non-conductive object like a dry wooden broom or plastic pole to push the victim away from the electrical source.
  3. Check the victim's responsiveness and breathing; if they are unconscious and not breathing, initiate CPR immediately.
  4. Call emergency services for professional medical assistance.
  5. Treat any visible burns by covering them with a sterile, non-stick bandage and keep the victim warm while waiting for help.
b

Explain in detail the location of switches and outlets used in the LT system.

8 marks

Answer

In an LT (Low Tension) system, the placement of switches and outlets is governed by safety standards to prevent accidental contact, moisture damage, and fire hazards. Key considerations for their location include:

  • Height Requirements: Switches are typically installed at a height of 1.2 to 1.5 meters from the floor level to ensure accessibility while remaining out of reach of small children. Power outlets (sockets) are generally placed 0.3 meters above the floor in living areas, but should be at least 1.0 to 1.2 meters above the floor in kitchens or workbenches to avoid spills and damage.
  • Proximity to Water: Switches and outlets must be located at a safe horizontal distance (typically at least 0.6 meters) from water sources like sinks, showers, or bathtubs to prevent short circuits caused by water splashes.
  • Accessibility and Convenience: Switches for lighting should be placed near the entrance of a room to allow for immediate illumination. Outlets should be distributed based on the load requirements of appliances, ensuring that heavy-duty appliances like refrigerators or washing machines have dedicated circuits and outlets located near the equipment.
  • Environmental Protection: In damp or outdoor locations, switches and outlets must be of an IP-rated (Ingress Protection) weatherproof design with protective covers to prevent the ingress of moisture and dust.
  • Clearance: Switches and outlets should not be placed behind doors or in locations where they may be obstructed by furniture, ensuring they remain accessible for maintenance and emergency disconnection.
215 marks
a

Is it necessary to use a fuse along with an MCB? How MCBs are different from circuit breakers used in power systems?

8 marks

Answer

Sign in to view the complete answer paper.

b

Write a short note on the Tariff structure.

7 marks

Answer

Sign in to view the complete answer paper.

315 marks
a

What is the difference between residential and commercial electrical systems? Explain.

7 marks

Answer

Sign in to view the complete answer paper.

b

How do you decide the rating of the main switch? Explain it with an example.

8 marks

Answer

Sign in to view the complete answer paper.

415 marks
a

Discuss about the various factors to be considered while deciding lighting scheme in a commercial building.

8 marks

Answer

Sign in to view the complete answer paper.

b

What is the function of a distribution board? And what are the protection devices installed in the distribution board?

7 marks

Answer

Sign in to view the complete answer paper.

5

Explain the design of a lighting scheme for a residential and commercial premise with a suitable example.

15 marks

Answer

Sign in to view the complete answer paper.

615 marks
a

What are the various types of light sources available? Explain about the operation of any two lighting sources.

9 marks

Answer

Sign in to view the complete answer paper.

b

Explain the functional differences between LED and CFL.

6 marks

Answer

Sign in to view the complete answer paper.

715 marks
a

What is the difference between MCC and PCC panels?

7 marks

Answer

Sign in to view the complete answer paper.

b

Write the significance of power factor correction Industrial Electrical Systems. How can it be improved? Explain about any one method.

8 marks

Answer

Sign in to view the complete answer paper.

815 marks
a

List out the advantages and disadvantages of DG systems with respect to other types of backup scheme

7 marks

Answer

Sign in to view the complete answer paper.

b

Explain the working of offline, online, and line interactive UPS with block diagrams.

8 marks

Answer

Sign in to view the complete answer paper.

About this paper

This page contains the solved question paper with answers of INDUSTRIAL ELECTRICAL SYSTEMS from JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD for B.Tech EEE IV Year I, February/March - 2022, R18.

For the question paper without answers, switch to the Question Paper tab.

Other papers in INDUSTRIAL ELECTRICAL SYSTEMS

Loading Question Papers

Fetching data from database...