What is load factor? How is it related to load factor? Explain its significance.

9 marks

Answer

Load factor is defined as the ratio of the average load over a designated period of time to the maximum peak load occurring in that same period. It is expressed as:

Load Factor = Average Load / Peak Load

The average load is calculated by dividing the total energy consumed during the period by the number of hours in that period. The load factor is always less than or equal to unity, as the average load can never exceed the peak load.

The significance of the load factor lies in its role as a measure of the utilization of the distribution system capacity. A high load factor indicates that the load is relatively constant, which allows for more efficient use of equipment and reduces the cost per unit of electricity generated and distributed. Conversely, a low load factor implies that the system is underutilized for most of the time, leading to higher capital costs per unit of energy delivered. Improving the load factor is essential for minimizing losses and optimizing the return on investment for distribution infrastructure.

b

The load curves of two different categories of loads and system peak load are as follows. Determine the diversity factor and coincidence factor for the system. Peak load for industrial load = 2000 kW; Peak load for residential load = 3000 kW and System peak load = 2500 kW.

6 marks

Answer

Given:

  • Peak load of industrial load (P_ind) = 2000 kW
  • Peak load of residential load (P_res) = 3000 kW
  • System peak load (P_sys) = 2500 kW

The diversity factor is the ratio of the sum of individual maximum demands to the maximum demand of the entire system:

Diversity Factor = (P_ind + P_res) / P_sys
Diversity Factor = (2000 + 3000) / 2500 = 5000 / 2500 = 2.0

The coincidence factor is the reciprocal of the diversity factor:

Coincidence Factor = 1 / Diversity Factor
Coincidence Factor = 1 / 2.0 = 0.5
215 marks
a

How do you choose the secondary feeder arrangement from reliability point of view? Discuss the arrangements with suitable diagrams.

8 marks

Answer

Sign in to view the complete answer paper.

b

Give a line diagram of loop (ring) type primary feeder system and mention the different component parts. What are the considerations for planning loop (ring) feeders?

7 marks

Answer

Sign in to view the complete answer paper.

315 marks
a

What are the factors to be considered for location of a Substation? What are the benefits obtained from optimal location of a Substation?

8 marks

Answer

Sign in to view the complete answer paper.

b

Explain how do you calculate the rating of a distribution substation?

7 marks

Answer

Sign in to view the complete answer paper.

415 marks
a

Discuss the method to analyze the distribution feeder cost.

8 marks

Answer

Sign in to view the complete answer paper.

b

Show that the power loss due to the load currents in conductors in a single phase two wire ungrounded system with full capacity neutral (3-wire system) is six times more than that in the equivalent 3-phase 4 wire system.

7 marks

Answer

Sign in to view the complete answer paper.

515 marks
a

Explain the co-ordination procedure between a main fuse and a sectional fuse?

8 marks

Answer

Sign in to view the complete answer paper.

b

A single phase, 3-wire distribution line 120V-0-120V, feeds a load of 10KVA line to line and 3KVA on each line to ground. The Transformer is 7620V/240V, 25KVA with 5% impedance. The line impedance is j0.05 per wire. Calculate the fault current and fault MVA for the following: i) L-L fault and ii) L-G fault, 1 km from Transformer.

7 marks

Answer

Sign in to view the complete answer paper.

615 marks
a

Explain the coordination procedure between a fuse and auto-recloser.

8 marks

Answer

Sign in to view the complete answer paper.

b

Explain the principle of operation of Circuit breaker.

7 marks

Answer

Sign in to view the complete answer paper.

715 marks
a

Compare and explain role of shunt and series capacitors in p.f correction.

8 marks

Answer

Sign in to view the complete answer paper.

b

An industry has a total induction motor load of 100 h.p, efficiency 90% and power factor 0.82 lagging. It is necessary to correct the p.f to 0.92 lagging. Determine the capacitor bank needed. If the capacitor bank has 3% losses, find the % increase in power take and the p.f with capacitors.

7 marks

Answer

Sign in to view the complete answer paper.

8

Explain the different methods for voltage control in distribution systems.

15 marks

Answer

Sign in to view the complete answer paper.