Define Reproducibility and Repeatability.
Answer
Repeatability is the ability of a measuring instrument to provide the same reading when the same input is applied repeatedly under identical conditions over a short period. Reproducibility is the ability of an instrument to provide the same reading when the same input is applied under different conditions, such as different operators, different locations, or different times.
A wattmeter having a range of 500 W has an error of ±2% of Full scale deflection. If the true power is 100 W, what would be the range of readings? Suppose the error is specified as percentage of true value, what would be the range of the readings?
Answer
Given: Range = 500 W, Error = ±2% of FSD. Absolute error = 0.02 × 500 = ±10 W. For a true power of 100 W, the range of readings is 100 ± 10 W, which is 90 W to 110 W.
If the error is ±2% of the true value, absolute error = 0.02 × 100 = ±2 W. The range of readings is 100 ± 2 W, which is 98 W to 102 W.
Define Fidelity and Dynamic Error.
Answer
Sign in to view the complete answer paper.
A temperature sensing device can be modeled as a first order system with a time constant of 5 seconds. It is suddenly subjected to a step input of 30°C – 150°C. What temperature will be indicated in 10 seconds after the process has started.
Answer
Sign in to view the complete answer paper.
Calculate the thermoelectric sensitivity of a device using bismuth and tellurium as dissimilar metals. Estimate the maximum output voltage for a 100°C temperature difference at room temperature using one junction. The sensitivity of bismuth is -72 µV/°C and that of tellurium is 500 µV/°C.
Answer
Sign in to view the complete answer paper.
Illustrate law of intermediate metals and law of intermediate temperatures, with figures.
Answer
Sign in to view the complete answer paper.
Define Torr and Micron.
Answer
Sign in to view the complete answer paper.
Draw the diagram of Pirani Gauge.
Answer
Sign in to view the complete answer paper.
A pitot tube is used for measurement of velocity of flow of water having a density of 1000 kg/m3. Determine the velocity of flow at the head of the pitot tube, if it produces a differential pressure of 10 kN/m2 between its two outlets.
Answer
Sign in to view the complete answer paper.
Compare Electromagnetic Flow meter with Ultrasonic Doppler Flow meter.
Answer
Sign in to view the complete answer paper.
PART - B
Draw the block diagram of a Generalized Measurement System and explain the function of each block.
Answer
Sign in to view the complete answer paper.
List out Static characteristics of a measurement system and discuss about sensitivity, linearity and resolution.
Answer
Sign in to view the complete answer paper.
Discuss the classification of Transducers based on principle of Transduction.
Answer
Sign in to view the complete answer paper.
Describe the Weston saturated and unsaturated cells as emf standards. What are the precautions taken while using them?
Answer
Sign in to view the complete answer paper.
Derive the expression for the response of 2nd order underdamped system when subjected to a Unit step input. Sketch the response.
Answer
Sign in to view the complete answer paper.
What are time domain specifications? Derive the expressions for Rise time and Peak time.
Answer
Sign in to view the complete answer paper.
A practical example of First Order System is the Liquid Filled Thermometer. Justify.
Answer
Sign in to view the complete answer paper.
Derive the expressions for magnitude and phase of a First order system when subjected to a sinusoidal input signal. Draw the magnitude and phase versus frequency plots. Describe how time constant and frequency of system influences response of First order system.
Answer
Sign in to view the complete answer paper.
Draw various forms of manometers and explain their features.
Answer
Sign in to view the complete answer paper.
Explain how different types of elastic transducers are used for pressure measurement.
Answer
Sign in to view the complete answer paper.
Why is cold junction compensation necessary in temperature measuring schemes using Thermocouples? What is the recent trend in making such compensation? Discuss about it.
Answer
Sign in to view the complete answer paper.
Discuss in detail the High Pressure Measurement.
Answer
Sign in to view the complete answer paper.
Discuss in brief determining magnitude of velocity from pitot-static tube, with a neat diagram.
Answer
Sign in to view the complete answer paper.
Discuss any one method of measurement of Sound, with neat diagram.
Answer
Sign in to view the complete answer paper.
With a neat sketch explain the working of constant current type hot wire anemometer and compare it with constant temperature type.
Answer
Sign in to view the complete answer paper.
Draw and explain the working of Knudsen Gauge.
Answer
Sign in to view the complete answer paper.
Describe the working of Drag-Force flow meters with a neat schematic.
Answer
Sign in to view the complete answer paper.
Show how a Rotameter scale is linearized? Is it permissible to mount a Rotameter horizontally? Justify.
Answer
Sign in to view the complete answer paper.
Name the different types of obstruction type flow meters and briefly discuss the advantages and disadvantages of them.
Answer
Sign in to view the complete answer paper.
Explain the working of positive Displacement meters with a neat diagram.
Answer
Sign in to view the complete answer paper.